Euler Column Buckling Example
Find the load at which a slender pinned column buckles, a standard FE structural column-analysis problem.
Concept
A long, slender column under axial compression can suddenly bow sideways (buckle) well before the material crushes. Euler's formula gives the critical load. It depends on the stiffness , the length squared, and the end conditions through the effective length factor .
- Pinned-pinned: . Fixed-fixed: 0.5. Fixed-pinned: 0.7. Cantilever (fixed-free): 2.0.
- A column buckles about its weak axis, so use the smaller .
- Convert units first: GPa times 1000 gives MPa (N/mm²), keep in mm, and divide the answer in N by 1000 for kN.
Check your answer with the column buckling calculator.
Problem
A steel column 6 m long is pinned at both ends and braced nowhere along its height. and the moment of inertia about its weak axis is . Assuming elastic (Euler) buckling, the critical buckling load is most nearly:
- 274 kN
- 1,097 kN
- 2,238 kN
- 4,387 kN
Given
- Length:
- Pinned-pinned:
- ,
Step 1: Convert units
Step 2: Numerator
Step 3: Denominator
Step 4: Critical load
Answer
Common Mistakes
- (A) 274 kN: using K = 2.0 (cantilever) for a pinned-pinned column.
- (C) 2,238 kN: using K = 0.7 (fixed-pinned) for a pinned-pinned column.
- (D) 4,387 kN: using K = 0.5 (fixed-fixed) for a pinned-pinned column.
- Using the strong-axis I: an unbraced column buckles about its weak axis, which gives the lower load.
- Mixing units: using L in m with E in MPa and I in mm⁴ is off by powers of 10.
Note: Euler's formula assumes elastic buckling; real steel design codes reduce this for stocky columns. For a related structural check, see the beam deflection example.
Key Formulas
Notation: = modulus of elasticity, = weak-axis moment of inertia, = effective length factor, = unbraced length.