PolyCalc

Rankine Active Earth Force Example

Find the total sideways push of dry sand on a retaining wall, a standard FE geotechnical calculation.

Dry sand backfillγ = 18 kN/m³, φ = 30°PaH = 5 mH/3

Problem

A vertical retaining wall 5 m high holds level, dry, cohesionless backfill with a unit weight of 18 kN/m³ and a friction angle of 30°. Assume a smooth wall and Rankine conditions.

The total active earth force on the wall per meter of wall length is most nearly:

  1. 75 kN/m
  2. 113 kN/m
  3. 150 kN/m
  4. 675 kN/m

Answer

Show steps

Given

  • Wall height:
  • Unit weight:
  • Friction angle:
  • Dry, level, cohesionless backfill; smooth wall

Step 1: Active earth pressure coefficient

Step 2: Total active force

Step 3: Where the force acts

Concept

When a wall is free to move slightly away from the soil, the backfill reaches the active state and pushes on the wall with the smallest possible lateral pressure. For dry cohesionless soil the pressure grows linearly with depth, so the pressure diagram is a triangle and its resultant is the area of that triangle.

  • Use for a wall that can move away from the soil. At-rest () applies to a wall that cannot move, and passive () applies when the wall is pushed into the soil.
  • The resultant of a triangular diagram acts at one third of the height above the base.
  • The answer is a force per meter of wall length (kN/m).
  • For vertical effective stress with a water table, see the effective stress example.

Want to check your answer? Try the retaining wall calculator and compare it with the hand calculation. For the full theory, read the lateral earth pressure lesson.

Key Formulas

Notation: = active earth pressure coefficient, = soil friction angle, = unit weight of soil, = wall height, = total active force per meter of wall.

Common Mistakes

  • (B) 113 kN/m: using the at-rest coefficient K0 = 1 - sin(φ) = 0.5 instead of Ka.
  • (C) 150 kN/m: forgetting the 1/2 in Pa = 1/2 Ka γ H², which is the triangle area factor.
  • (D) 675 kN/m: using the passive coefficient Kp = 3 instead of Ka.
  • Placing the resultant at H/2 instead of H/3 for the triangular pressure diagram.

Note: Water behind the wall adds hydrostatic pressure; this problem assumes dry backfill.