Retaining Wall Calculator

Check a cantilever retaining wall for overturning, sliding and bearing pressure using Rankine active earth pressure, with an optional surcharge.

Cantilever wall

Level backfill, front face of the stem battered, back face vertical. Heel = B − toe − stem base thickness.

Stability checks

  • Overturning FS = ΣMr / ΣMo: 3.945 (need ≥ 2.0)OK
  • Sliding FS = μΣV / ΣH: 1.639 (need ≥ 1.5)OK
  • Max bearing pressure (psf): 1,539 (allowable 3,000)OK
  • Resultant in middle third: e = 0.406 ft (|e| ≤ B/6 = 1.333)OK

Ka = 0.333 · heel = 4.5 ft · ΣV = 9,439 lb/ft · ΣH = 2,880 lb/ft · qmin = 820.9 psf

ForceValue (lb/ft)Arm about toe (ft)Moment (lb·ft/ft)
Stem (rectangle)1,57534,725
Stem (taper)393.82.333918.8
Base1,80047,200
Soil over heel5,6705.7532,600
Active soil pressure (overturning)2,880411,520

Preliminary stability check only. Passive pressure at the toe and the surcharge weight over the heel are ignored (conservative). Stem and base reinforcement, global stability, seismic loads and drainage need a licensed engineer's design.

How the Calculator Checks a Retaining Wall

A cantilever wall resists the soil behind it with its own weight plus the weight of the soil sitting on its heel. The calculator works per unit length of wall (per foot or per metre) and runs the three classic stability checks: overturning about the toe, sliding along the base, and soil bearing pressure under the base.

Lateral pressure uses Rankine active earth pressure for level backfill, acting on a vertical plane through the heel over the full height H. Passive pressure in front of the toe is ignored, as is common, because that soil can be dug out later.

Rankine Earth Pressure Formulas

Pa is the triangular soil pressure resultant and Pq the rectangular pressure from a uniform surcharge q (traffic, a slab, stockpiles). These match the Horizontal Stress Profiles and Forces and Retaining Walls entries in the Geotechnical section of the NCEES FE Reference Handbook 10.5 (Civil Engineering chapter, from page 259). For the theory, see the lateral earth pressure lesson.

Overturning, Sliding and Bearing

Moments are taken about the toe. When |e| > B/6 the resultant leaves the middle third, part of the base lifts off, and the pressure becomes a triangle: qmax = 2ΣV / (3a), with a = B/2 − |e|. The base friction coefficient μ is tan δ, often taken as about 0.5 to 0.6 for concrete cast on granular soil.

Worked Example

A wall is 12 ft tall overall with a 1.5 ft thick, 8 ft wide base and a 2 ft toe. The stem tapers from 1 ft at the top to 1.5 ft at the base, so the heel is 8 − 2 − 1.5 = 4.5 ft. Backfill: γ = 120 pcf, φ = 30°. Concrete: 150 pcf. μ = 0.5. These are the calculator's default US inputs.

ForceW (lb/ft)Arm (ft)Moment (lb·ft/ft)
Stem rectangle 1 × 10.5 × 1501,5753.004,725
Stem taper ½ × 0.5 × 10.5 × 1503942.33919
Base 8 × 1.5 × 1501,8004.007,200
Soil 4.5 × 10.5 × 1205,6705.7532,603
Total9,43945,446

Ka = 1/3, so Pa = ½ × (1/3) × 120 × 12² = 2,880 lb/ft at 4 ft, an overturning moment of 11,520 lb·ft/ft.

Now add a 250 psf surcharge. Pq = (1/3)(250)(12) = 1,000 lb/ft at 6 ft, so ΣMO = 17,520 and FSOT = 2.59, still fine. Sliding drops to 0.5 × 9,439 / 3,880 = 1.22, which fails, and qmax rises to 2,101 psf. The usual fix is a shear key or a longer heel. Enter q = 250 in the calculator above and try a wider base to see how much it takes.

Sizing Rules of Thumb

Start with a base width B of about 0.5H to 0.7H, base and stem-base thickness of about 0.1H, a stem top of at least 8 to 12 in (0.2 to 0.3 m), and a toe of about B/3 to keep the resultant near the middle third.

Once the wall is stable, size the concrete with the footing calculator and the bars with the rebar calculator. For the drainage stone behind the wall, the gravel calculator gives tons from length, height and thickness. For a block stem, the concrete block calculator counts units and grout. Retaining structures are subtopic E of FE Civil geotechnical engineering.

Retaining Wall FAQ

What factor of safety is required for a retaining wall?

Common minimums are 2.0 against overturning (1.5 in some codes when the resultant stays in the middle third) and 1.5 against sliding. Bearing pressure must stay below the allowable soil bearing pressure, which already includes a factor of safety of about 3.

What is the Rankine active earth pressure coefficient?

For level backfill against a smooth vertical plane, Ka = (1 − sin φ)/(1 + sin φ) = tan²(45° − φ/2). For φ = 30°, Ka = 1/3, so a wall retaining 120 pcf soil sees a lateral pressure that grows by 40 psf per foot of depth.

Why is the earth pressure taken through the heel instead of on the stem?

The soil sitting on the heel moves with the wall, so the stability check treats wall plus heel soil as one block. The active wedge acts on a vertical plane through the back of the heel, over the full height H including the base.

What if my wall fails sliding?

Widen the base, lengthen the heel (more soil weight), add a shear key under the base, or count passive pressure in front of the toe if that soil is reliably there for the life of the wall.

Can I use this calculator to design a retaining wall?

Use it for preliminary sizing and for checking homework or FE exam problems. A real wall also needs stem and base reinforcement design, global stability, drainage and often seismic loads, designed by a licensed engineer.

Related tools and topics