PolyCalc

Rational Method Peak Runoff in SI Units

Estimate the peak runoff from a catchment with mixed land uses: weight the runoff coefficient by area, then apply the SI form of the rational method.

Parkland0.5 km², C = 0.20Commercial0.7 km², C = 0.80Total catchment A = 1.2 km²i = 45 mm/h (duration = t_c)

Problem

A 1.2 km² urban catchment is made up of 0.5 km² of parkland () and 0.7 km² of commercial area (). The design rainfall intensity for a duration equal to the time of concentration is 45 mm/h. Using the rational method:

The peak runoff is most nearly:

  1. 7.5 m³/s
  2. 12.0 m³/s
  3. 8.3 m³/s
  4. 29.7 m³/s

Answer

Show steps

Given

  • Parkland ,
  • Commercial ,
  • Total area
  • Intensity (duration equal to )

Step 1: Area-weighted runoff coefficient

The two land uses cover different areas, so weight each coefficient by its area:

Step 2: Rational method in SI units

Check: in mixed units (mm/h and km²). The factor 0.278 converts this to m³/s: .

Concept

The rational method gives the peak discharge from a small catchment when rainfall of a given intensity falls for a duration equal to the time of concentration, so the whole catchment is contributing at once.

  • The runoff coefficient is the fraction of rainfall that becomes runoff: low for parkland, high for paved or built-up areas.
  • For a catchment with several land uses, use the area-weighted , not a simple average.
  • The intensity must be for a duration equal to .

0.278 converts (mm/h)(km²) to m³/s; in US units Q = CiA with in/hr and acres gives cfs directly. For a US-unit version, see the Water Resources and Environmental Engineering lessons, and for open-channel flow see Manning Equation: Trapezoidal Channel.

Key Formulas

Notation: = peak runoff, = runoff coefficient (dimensionless), = rainfall intensity for duration , = catchment area, = area-weighted runoff coefficient.

Common Mistakes

  • (A) 7.5 m³/s: averaging C without area weights, (0.20 + 0.80)/2 = 0.50.
  • (B) 12.0 m³/s: using only the commercial C = 0.80, the dominant land use, for the whole catchment.
  • (D) 29.7 m³/s: leaving out the 0.278 factor, i.e. using the US form Q = CiA with SI inputs.
  • Also check the duration: use the intensity for a storm equal to t_c, not a shorter or longer one.