Water and Wastewater Treatment (FE Civil)

NCEES FE Civil spec: Water Resources and Environmental Engineering, K. Water and wastewater treatment (e.g., biological processes, softening, drinking water treatment). FE Reference Handbook: Environmental Engineering chapter (Water Treatment Technologies, Wastewater Treatment and Technologies, Disinfection).

What the FE Civil Spec Covers

Section K covers drinking water and wastewater treatment: physical processes (screening, sedimentation, filtration), chemical processes (coagulation, softening, disinfection) and biological processes (activated sludge, trickling filters, digestion). FE problems are mostly loading rate and mass balance calculations, so a few formulas cover most of the questions.

Key Concepts

  • Drinking water train. A conventional surface water plant uses rapid mix with a coagulant (alum or ferric), flocculation, sedimentation, granular media filtration and disinfection. Hard groundwater may get lime-soda softening.
  • Wastewater train. Preliminary (screens, grit), primary clarification, secondary biological treatment (activated sludge or fixed film) with secondary clarifiers, disinfection, and sludge thickening and digestion.
  • Ideal settling. A basin removes every particle whose settling velocity is at least the overflow rate. Depth does not affect removal in the ideal model; surface area does.
  • Softening. Lime removes carbonate hardness; soda ash is also needed for noncarbonate hardness.
  • Disinfection. Inactivation depends on the product of residual concentration and contact time, CT. Chlorine demand is the dose minus the residual.
  • Activated sludge. Microorganisms (MLSS or MLVSS) consume BOD in an aerated tank. The food-to-microorganism ratio (F/M) and solids retention time (SRT) control performance. Conventional plants commonly run near an F/M of 0.2 to 0.4 per day and an SRT of roughly 5 to 15 days.

Core Formulas

Hydraulic detention time and surface overflow rate:

Stokes law for a discrete particle in laminar settling, and fraction removed in an ideal basin:

Weir loading and filter loading rate:

Disinfection and chemical feed (US units):

Example: dosing 2.5 mg/L of chlorine into a 5 MGD flow needs (2.5)(5)(8.34) = 104 lb/day. If the measured residual is 0.8 mg/L, the chlorine demand is 2.5 minus 0.8 = 1.7 mg/L, and a 30 minute contact time at that residual gives CT = 0.8 × 30 = 24 mg·min/L.

Activated sludge (S0 influent BOD, X MLSS, Qw and Xw waste sludge flow and concentration):

Where It Is in the FE Reference Handbook

The Environmental Engineering chapter has Water Treatment Technologies (clarifiers, settling equations, filtration, lime-soda softening, coagulation, mixing), Wastewater Treatment and Technologies (activated sludge, trickling filters, digestion) and Disinfection (CT and removal requirements).

Worked Example: Sedimentation Basin Check

A water plant treats 0.25 m³/s in two identical rectangular basins, each 40 m long, 10 m wide and 3.5 m deep. Find the overflow rate, detention time, and the fraction of particles with a settling velocity of 0.20 mm/s that are removed.

Step 1: Flow per basin.

Step 2: Overflow rate. Surface area A = 40 × 10 = 400 m².

Step 3: Detention time. V = 400 × 3.5 = 1,400 m³.

Step 4: Removal. Convert the settling velocity to m/day.

About 64 percent of those particles settle out. To remove them all, the overflow rate would have to drop to 17.28 m/day, which means about 625 m² of surface per basin.

Common Mistakes

  • Using total plant flow for one basin when the flow is split among several units.
  • Thinking a deeper basin removes more particles. In the ideal model, only surface area matters.
  • Leaving settling velocity in mm/s while the overflow rate is in m/day.
  • Using the chlorine dose instead of the residual in CT.
  • Mixing MLSS and influent BOD units in F/M, or including recycle flow in the F/M numerator.

Practice Problems

Try these from the free PolyCalc FE Civil problem bank. Each one has a full worked solution.

Related Calculators and Examples

Frequently Asked Questions

What is the surface overflow rate of a clarifier?

The overflow rate is the flow divided by the clarifier surface area, in units like m3/m2/day (m/day) or gpd/ft2. It equals the settling velocity of the smallest particle that an ideal basin removes completely; slower particles are removed in proportion to their settling velocity divided by the overflow rate.

What is the 8.34 factor in treatment calculations?

One million gallons of water weighs about 8.34 million pounds, so a concentration of 1 mg/L in a flow of 1 MGD is 8.34 lb/day. Mass loading in lb/day equals concentration in mg/L times flow in MGD times 8.34.

What is the difference between HRT and SRT in activated sludge?

Hydraulic retention time is the tank volume divided by the flow, often a few hours. Solids retention time (sludge age) is the mass of biomass in the system divided by the mass wasted per day, often several days, because clarifier recycle keeps the microorganisms in the system much longer than the water.

Back to all Water Resources and Environmental Engineering topics