Manning's Equation Calculator

Find the discharge for a given flow depth, or the normal depth for a given flow, in a rectangular, trapezoidal or triangular channel or a partly full circular pipe. Results include velocity, hydraulic radius, Froude number and critical depth.

Normal depth: 1.29 ft, velocity 5.59 ft/s

  • Discharge Q 12 cfs
  • Depth ratio y/D 0.646
  • Flow area A 2.15 ft²
  • Wetted perimeter P 3.74 ft
  • Hydraulic radius R = A/P 0.575 ft
  • Top width T 1.91 ft
  • Froude number Fr 0.93 (subcritical)
  • Critical depth yc 1.24 ft
  • Pipe flowing full: Q, V 16 cfs, 5.09 ft/s

Uniform flow: S is the bed slope and equals the energy slope. k = 1.486.

Manning's Equation

The equation assumes steady, uniform flow: the depth does not change along the reach, so the water surface, the bed and the energy grade line are parallel. That depth is the normal depth. Manning's equation is in the NCEES FE Reference Handbook, along with a hydraulic elements graph for partly full circular pipes.

Section Geometry

For depth y, bottom width b and side slope z (z horizontal to 1 vertical):

A rectangle is the same with z = 0, and a V-shaped (triangular) channel is the same with b = 0. For a circular pipe of diameter D, use the central angle θ of the wetted arc, in radians:

Full and half-full pipes both have RH = D/4, which is a handy check.

Manning n Values

SurfaceTypical n
PVC / HDPE smooth pipe0.010
Concrete pipe, vitrified clay0.013
Finished concrete channel0.015
Asphalt lined channel0.016
Corrugated metal pipe0.024
Earth channel, clean, straight0.022
Earth channel, gravel or some grass0.025
Natural stream, clean0.035
Natural stream, weeds or stones0.050

These are common design values; published ranges are wide (a clean earth channel runs from about 0.018 to 0.025, a natural stream from 0.025 to over 0.1). On the FE exam, n is usually given or read from a handbook table. A small change in n changes Q by the same percentage, so pick it with care in real design.

Worked Example: 24-inch Storm Sewer

A 24-inch concrete storm sewer (n = 0.013) is laid at S = 0.005. Find the full-pipe capacity, then the depth and velocity when it carries a design flow of 12 cfs. These are the calculator's default inputs.

  1. Full pipe: D = 2 ft, A = π(2)²/4 = 3.142 ft², RH = D/4 = 0.5 ft.
  2. Ratio: Q/Qfull = 12/16.0 = 0.75. The table below (or the handbook graph) puts that at about y/D = 0.65.
  3. Check y = 1.292 ft (y/D = 0.646): θ = 2 cos⁻¹(1 − 1.292) = 3.735 rad, A = (4/8)(3.735 − sin 3.735) = 2.147 ft², P = 2(3.735)/2 = 3.735 ft, RH = 0.575 ft.
  4. Velocity V = 12.0 / 2.147 = 5.59 ft/s, faster than the full-pipe 5.09 ft/s. That is normal for a pipe between half and about 80% full, and it is above the 2 to 3 ft/s minimum usually required to keep a sewer self-cleaning.
  5. Froude number: top width T = D sin(θ/2) = 1.913 ft, hydraulic depth A/T = 1.123 ft, Fr = 5.59 / √(32.174 × 1.123) = 0.93. Subcritical, but close to critical (yc = 1.24 ft), so expect a wavy, unstable surface. Designers often try to avoid Froude numbers near 1.

Answer: normal depth 1.29 ft (15.5 in), velocity 5.59 ft/s, capacity 16.0 cfs flowing full. For an open trapezoidal channel solved the same way, see the Manning equation FE lesson, which works a 10 ft earth channel to 206 cfs (check it with Trapezoidal, b = 10 ft, z = 2, y = 3 ft, n = 0.025, S = 0.002).

Partly Full Circular Pipes

y/DQ/QfullV/Vfull
0.20.0880.62
0.40.340.90
0.50.501.00
0.60.671.07
0.80.981.14
0.941.081.10
1.01.001.00

Values assume n does not change with depth, which is the solid curves on the handbook's hydraulic elements graph. Flow peaks at y/D ≈ 0.94, so a sewer sized to run "just full" actually has about 8% reserve. If the design flow is more than 1.08 Qfull, no part-full depth works and the pipe surcharges; the calculator flags that case.

Manning on the FE Civil Exam

Most questions give three of Q, geometry, n and S and ask for the fourth. Solving for Q, V, n or S is direct. Solving for depth or pipe diameter needs trial values: on a multiple choice question, plug each answer choice in and keep the one that returns the given flow. Watch the units (1.486 with feet, 1.0 with meters) and use RH, not the depth. Practice with the hydraulics practice deck, and see the collection systems lesson for sewer sizing.

Manning's Equation FAQ

What is Manning's equation?

An empirical formula for uniform flow in open channels and pipes flowing partly full: Q = (k/n) A R^(2/3) S^(1/2), where k = 1.486 in US units (ft, cfs) and 1.0 in SI (m, m³/s), n is the roughness coefficient, A the flow area, R = A/P the hydraulic radius and S the slope.

Why is the constant 1.486 in US units?

n is defined in SI units. Converting the equation to feet multiplies it by (3.2808 ft/m)^(1/3) = 1.486. Because the constant absorbs the conversion, the same n value works in both systems.

How do you solve Manning’s equation for depth?

Depth sits inside both A and R, so there is no closed form. Guess a depth, compute Q, and adjust until it matches the design flow (bisection or trial and error). The calculator does this automatically in "Find depth from Q" mode.

Does a pipe carry the most water when it is full?

No. With a constant n, a circular pipe carries its maximum flow at about 94% of its diameter, roughly 8% more than when full, because the last bit of depth adds a lot of wetted perimeter at the crown. Velocity peaks at about 81% depth.