Enter the flow, pipe size, length and material. The calculator gives the friction head loss and pressure drop by Darcy-Weisbach (Colebrook friction factor) and by Hazen-Williams, plus minor losses.
Full pipe, water or any liquid
Water: ν = 1.217×10⁻⁵ ft²/s at 60°F, 1.004×10⁻⁶ m²/s at 20°C.
Head loss (Darcy-Weisbach): 17.3 ft = 7.49 psi
Velocity V6.3 ft/s
Reynolds number Re174,000 (turbulent)
Relative roughness ε/D0.000447
Friction factor f (Colebrook)0.01881
Velocity head V²/2g0.617 ft
Hazen-Williams friction loss23.1 ft = 9.99 psi
Hazen-Williams is only valid for water at ordinary temperatures in turbulent flow. Pressure assumes water (62.4 lb/ft³, 9.79 kN/m³).
What Head Loss Means
Head loss is the energy a liquid loses to friction as it moves through a pipe, written as a height of the liquid (ft or m). It appears in the energy equation between two points:
hf is the major loss from friction along straight pipe; hm is the minor loss from fittings, valves, entrances and exits. In a level pipe of constant size, the whole loss shows up as a pressure drop, Δp = γhf. For water, divide feet of head by 2.31 to get psi.
Darcy-Weisbach Equation
hf=fDL2gV2Re=νVDV=πD2/4Q
The Darcy friction factor f depends on the Reynolds number and the relative roughness ε/D. For laminar flow (Re below about 2,000) f = 64/Re. For turbulent flow the calculator solves the Colebrook equation, which is what the Moody diagram plots:
f1=−2log10(3.7ε/D+Ref2.51)
Colebrook has f on both sides, so it is solved by iteration. The explicit Swamee-Jain formula, f = 0.25 / [log10(ε/3.7D + 5.74/Re0.9)]², lands within about 1% and is a good exam shortcut. Darcy-Weisbach, the Moody diagram and the minor loss coefficients are in the Fluid Mechanics chapter of the NCEES FE Reference Handbook.
Hazen-Williams Equation
V=kCRH0.63S0.54S=LhfRH=4D(full pipe)
k = 1.318 in US units (ft, s) and 0.849 in SI (m, s). Solved for head loss with Q in gpm and d in inches, the common form is hf = 10.44 L Q1.85 / (C1.85 d4.87). A higher C means a smoother pipe and less loss. The FE Handbook gives Hazen-Williams, with a table of C values, in the Civil Engineering chapter (hydrology and water resources). It is only valid for water near room temperature in turbulent flow.
Roughness and C Values
Pipe material
ε (mm)
ε (ft)
Hazen-Williams C
PVC / plastic
0.0015
0.0000049
150
Copper / drawn tubing
0.0015
0.0000049
140
Commercial steel
0.045
0.00015
120
Galvanized iron
0.15
0.00049
120
Cast iron
0.26
0.00085
100
Ductile iron, cement lined
0.12
0.00039
140
Concrete
1
0.0033
130
These are typical textbook values. ε is for new pipe; the C values are common design values that allow for some aging. Concrete roughness varies from about 0.3 to 3 mm with finish.
Worked Example: 250 gpm in a 4-inch Steel Pipe
Water at 60°F (ν = 1.217×10⁻⁵ ft²/s) flows at 250 gpm through 500 ft of 4-inch Schedule 40 commercial steel pipe (inside diameter 4.026 in, ε = 0.00015 ft). Find the friction head loss and pressure drop. These are the calculator's default inputs.
Flow: Q = 250 / 448.8 = 0.5570 ft³/s. D = 4.026 / 12 = 0.3355 ft, A = π(0.3355)² / 4 = 0.08840 ft², so V = 0.5570 / 0.08840 = 6.30 ft/s.
Colebrook (starting from Swamee-Jain, f = 0.0189) converges to f = 0.0188.
Velocity head V²/2g = 6.30² / (2 × 32.174) = 0.617 ft. hf = 0.0188 × (500 / 0.3355) × 0.617 = 17.3 ft.
Pressure drop: Δp = 17.3 × 62.4 / 144 = 7.5 psi.
Hazen-Williams with the design value C = 120 gives about 23 ft (10 psi), a third more. With C = 140, the value for new steel, it gives 17.3 ft and matches Darcy-Weisbach. That gap is the aging allowance built into the design C. If the line also has fittings with ΣK = 2.0, add hm = 2.0 × 0.617 = 1.2 ft, for a total of 18.5 ft (8.0 psi). For an SI version of the same steps, see the Darcy-Weisbach FE example (switch the calculator to SI to check it: 4.21 m).
Using Head Loss for Pumps and the FE Exam
The total dynamic head a pump must supply is the elevation rise plus hf plus hm (plus any pressure difference). Pump power is then P = γQh / η. FE Civil problems on pipe flow almost always reduce to the steps above; practice them in the hydraulics practice deck and the pumps lesson.
Pipe Head Loss FAQ
How do you calculate head loss in a pipe?
Find the velocity V = Q/A, the Reynolds number Re = VD/ν and the relative roughness ε/D. Get the friction factor f from the Moody diagram or the Colebrook equation, then hf = f (L/D) V²/2g. Add minor losses ΣK V²/2g for fittings and valves.
Should I use Darcy-Weisbach or Hazen-Williams?
Darcy-Weisbach works for any liquid, any temperature and laminar or turbulent flow, so it is the more general method. Hazen-Williams is an empirical formula for water in turbulent flow; water utilities use it because the C value is a single number that does not depend on velocity.
How do I convert head loss to pressure drop?
Multiply by the specific weight: Δp = γ hf. For water, 1 psi is 2.31 ft of head, so divide feet of head by 2.31. In SI, 1 m of water is about 9.79 kPa.
Why do the two methods give different answers?
The roughness ε describes a new pipe, while design C values such as 120 for steel or 100 for cast iron already allow for aging and tuberculation. Hazen-Williams with a design C is usually more conservative. Match them by using the C of a new pipe (about 140 for new steel).